THIS WEBSITE USES COOKIES
This site uses cookies in order to deliver services in accordance with Privacy Policy. You can use settings within your browser to control the cookies that are set on your computer – conditions of access or storage of cookies.
Do not show this again
Download image
URBINO LED
PLUS version
Professional streetlight luminaire for LED light sources.



High efficacy to 154 lm/W
Possible illuminance control
Modern design
Reliability

Application

area lighting, avenues, cycle paths, express roads, local roads, parking areas, pedestrian crossings, promenade, public spaces, residential area roads, town roads

Available on request

10kV surge protection, CLO, Colour temperature - 5700K, DIM 1..10V, NEMA connector, NTC, ZHAGA connector, extension of the warranty to 10 years, knife switch, twilight sensor, version with increased corrosion resistance in accordance with class C5

Luminous flux range

9750 - 30700 [lm]

Variable color temperature

2200 - 4000 [K]

Mechanical data

Mounting
on pillar ø40-60mm, on pillar ø76mm - modification .829, on outriggers ø40-60mm, on outriggers ø76mm - modification .829
Body colour
graphite, gray
Operating temperature range
-40 ... +50
RAL
7035
Body
high pressure die-cast aluminum
Lateral Surface Wind Exposed
0.045 m²
Type
PLUS version - O62, O63, O64, O65, O66, O67, O68, O69, O70, O71, O86, O87, O98, O99 optics, PLUS version - O73, O74, O75, O76, O77, O78, O79, O80, O81, O82, O96, O97 optics, PLUS version - O93, O94, O95 optics

Electrical data

Power supply efficiency
≤90%
Power
220-240V 50/60Hz
Includes light source
yes
Luminaire power [W]
101 - 205
Output current [mA]
700, 1050
Type of equipment
DALI, ED
Maximum number of luminaires in the circuit with a 10A fuse (B)
4 - 7
Maximum number of luminaires in the circuit with a 16A fuse (B)
8 - 12
Maximum number of luminaires in the circuit with a 25A fuse (B)
13 - 19

Optical data

Way of lighting
direct
Type of optic
O62 - for express roads, O63 - for local roads, O64 - for town roads, O65 - for residential area roads, O66 - for pedestrian crossings, left side traffic, O67 - for pedestrian crossings, right side traffic, O68 - for area lighting, O69 - for town and local roads, O70 - for wet surfaces, O71 - for road lighting, O73 - for express roads, O74 - for local roads, O75 - for town roads, O76 - for residential area roads, O77 - for pedestrian crossings, left side traffic, O78 - for pedestrian crossings, right side traffic, O79 - for area lighting, O80 - for town and local roads, O81 - for wet surfaces, O82 - for road lighting, O86 - for road lighting, O87 - for road lighting, O93 - for road lighting, O94 - for road lighting, O95 - for road lighting, O96 - for road lighting, O97 - for road lighting, O98 - for road lighting, O99 - for road lighting
Diffuser
tempered glass
Colour temperature [K]
2200, 2700, 3000, 4000
CRI/Ra
>70
MacAdam's steps
5
ULOR / DLOR
0% / 100%
Lumen luminaire [lm]
9750 - 30700
Efficacy [lm/W]
83 - 154
Photobiological risk group
RG1
Number of LEDs
48, 96

General data

Additional equipment
tool-free access to the power supply compartment by means of clips (index extension: .865), additional anti-corrosive protection (index extension: .985), luminaire with holder for mounting on a ø76mm pillar (index extension: .829), luminaire with motion detector (index extension: .870 / .871 / .872) - available as standard with ø60mm adjustable handle with adjustment range of -110° to +55°/-20° to +145°, ø60mm adjustable bracket with an adjustment range of -110° to +55°/-20° to +145° (index extension: .867)
Additional information
Tilt adjustment: -15° to +15° (every 5°), CRI/Ra >70
Other remarks
the pole and boom are not part of the luminaire
Lifetime L90B10
100 000 h
Warranty
5 years

Dimensions

Dimensions [mm] LxWxH Mounting dimensions [mm] ØS Pallet quantity Quantity in package Net weight [kg]
670x320x105 60 20 1 10.3
X

Available variants

Code
Colour temperature [K]
2200
2700
3000
4000
Lumen luminaire [lm]
Luminaire power [W]
Efficacy [lm/W]
Type of equipment
DALI
ED
Body colour
graphite
gray
Type of optic
O62 - for express roads
O63 - for local roads
O64 - for town roads
O65 - for residential area roads
O66 - for pedestrian crossings, left side traffic
O67 - for pedestrian crossings, right side traffic
O68 - for area lighting
O69 - for town and local roads
O70 - for wet surfaces
O71 - for road lighting
O73 - for express roads
O74 - for local roads
O75 - for town roads
O76 - for residential area roads
O77 - for pedestrian crossings, left side traffic
O78 - for pedestrian crossings, right side traffic
O79 - for area lighting
O80 - for town and local roads
O81 - for wet surfaces
O82 - for road lighting
O86 - for road lighting
O87 - for road lighting
O93 - for road lighting
O94 - for road lighting
O95 - for road lighting
O96 - for road lighting
O97 - for road lighting
O98 - for road lighting
O99 - for road lighting
Protection Class
I
II
Clear Filters
Compare Code Protection Class Type of optic Type of equipment Luminaire power [W] Lumen luminaire [lm] Efficacy [lm/W] Colour temperature [K] Operating temperature range
130222.3L031.381 I O62 - for express roads DALI 103 12750 124 2700 -40 ... +50
130222.3L031.391 I O63 - for local roads DALI 103 12600 122 2700 -40 ... +50
130222.3L031.401 I O64 - for town roads DALI 103 12650 123 2700 -40 ... +50
130222.3L031.411 I O65 - for residential area roads DALI 103 12700 123 2700 -40 ... +50
130222.3L031.421 I O66 - for pedestrian crossings, left side traffic DALI 103 12900 125 2700 -40 ... +50
130222.3L031.431 I O67 - for pedestrian crossings, right side traffic DALI 103 12900 125 2700 -40 ... +50
130222.3L031.441 I O68 - for area lighting DALI 103 12700 123 2700 -40 ... +50
130222.3L031.451 I O69 - for town and local roads DALI 103 12600 122 2700 -40 ... +50
130222.3L031.461 I O70 - for wet surfaces DALI 103 12650 123 2700 -40 ... +50
130222.3L031.471 I O71 - for road lighting DALI 103 12250 119 2700 -40 ... +50
Compare selected
Shown 10 / 2640
Show all
Compliant with British Standards: BS 5489-1 2020; BS EN 13201 2015; BS EN 60598-2-3:2003+A1:2011 and BS EN IEC 60598-1:2021+A11:2022.

Please note that the standard luminaire is not intended for use in an environment with an increased corrosivity category. The use of the luminaire for work in an environment for which additional corrosion protection is necessary requires the use of an index with the extension .985 (on request).
In order to apply the luminaire in an aggressive environment, for example with an increased concentration of sulfur, salt or other aggressive substances, a consultation with the LUG Technical Preparation of Production Branch is required.
Luminous flux tolerance +/- 10%.
Power tolerance +/- 5%.
Lighting beam, light intensity distribution and light efficiency were examined in accordance with the EN ISO 17025:2005 norm for EN13032 norm series and the LM-79 norm.
Up-to-date product info and General Warranty Terms available on our website www.luglightfactory.com
Detailed information on luminous fluxes and powers for individual indexes are indicated on the product data sheet.
The parameters in the data sheet are given for Ta=25°C.
The operating temperature ranges apply only to luminaires used in the outdoor environment.
Colour temperature tolerance +/- 5%.
Download Materials
Select and download the materials you are interested in
To download
Product sheet
Declarations and certificates
Light beam curves
3D/2D models
Mounting instruction
Download selected
CUSTOMISATION - OUR SETTING YOUR WAY
A luminaire, according to the Journal of Standards, is a device that is used to distribute, filter and convert the light output from one or more light-emitting sources, which is located in the mains
custom
Customisation
Bespoke - Let's develop a project together
A luminaire, according to the Journal of Standards, is a device that is used to distribute, filter and convert the light output from one or more light-emitting sources, which is located in the mains
bespoke
Bespoke
Accessories
150175.01351
150172.01350
Side louvers for URBINO LED PLUS luminaires
150175.01349
150172.01348
Rear-side louvers for URBINO LED PLUS luminaires